extend your senses
KOS
CALORIMETRIC FLOW SWITCH FOR EXPLOSIVE ATMOSPHERES FS 10Ex/11Ex/15Ex/20Ex

CALORIMETRIC FLOW SWITCH FOR EXPLOSIVE ATMOSPHERES FS 10Ex/11Ex/15Ex/20Ex

CALORIMETRIC FLOW SWITCH FOR EXPLOSIVE ATMOSPHERES FS 10Ex/11Ex/15Ex/20Ex
On request

BBB

--%>

It is a device that monitors the flow of fluid based on calorimetry principle. If the flow rate drops below a limit set by user, the status output is changed. The flow rate is displayed by ten LEDs and it is possible to select a boundary for contact making/breaking in the same graduation. The measuring cycle takes from 4 sec to 8 sec with the recommended measurement range 4 ÷ 150 cm/sec. In case of an empty pipeline, the sensor behaves in the same way as with zero flow.

Made in four versions as follows:

  • FS 10Ex – 1× status output (depending on flow velocity)
  • FS 11Ex – 2× status output (depending on flow velocity)
  • FS 15Ex – 2× status output (1× depending on flow velocity and 1× on temperature)
  • FS 20Ex – 1× status output and 1× current output (depending on flow velocity)

Meter states displayed

The flow switch point on LED scale can be implemented using two colours (red LED or amber LED), indicating at the same time which contact is normally closed or normally, open. In case of FS15, the temperature switch point is indicated by the LED located between the control push buttons. If the temperature of media is above/below the set-point, the LED is red, indicating that PIN2 is open at the same time (the sensor supplied as standard is configured open at a temperature above the set limit with the LED turned ON). If the logic of the normally open/normally closed point is changed by the user, the logic of both outputs is changed at the same time (applicable to FS 11 and FS15 versions).

The flow switch has two flush-type control buttons, making it possible:

  • the switching point/points for flow velocity (temperature in some case)
  • to change the logic of the N.O./N.C. output
  • to calibrate the minimum and maximum flow values of the monitoring device
  • to reset the original parameters from factory

ACCESSORIES 

Technické parametry

Type sensor FS 10Ex/11Ex/15Ex/20Ex
Power supply 24V±10%DC with polarity reversal protection
Input power 1,5/4 VA
Electrical connection connector M12x1 (4PIN)
Process connection

according to DIN2353 with the M16 × 1,5 union nut through the 24°
ring into the direct socket with pipe thread (G1/2“; G1/4“; M14 × 1,5; NPT1/4“)

Sensor design compact, separated (standard 3 m cable)
Image
10× three-colour LED (flow velocity)
1× LED (temperature – for FS 15 only)
Output types relay relay (for FS 10Ex), PNP, NPN, 4 ÷ 20 mA (for FS 20Ex only)
Contact rating 130 mA / 60 V / 500 mW
Response time* 1÷6 s
Velocity flow range 4÷400 cm/s
Accuracy ±2÷±8 cm/s
Hysteresis 2÷8 cm/s
Control 2× flush-mounted button
Temperature of liquid -10÷+80 °C
Ambient temperature -20÷+55 °C
Material in contact with medium stainless steel 1.4404
Maximum pressure 64 bar
Degree of protection IP67
Ambient humidity max. 90 %
Status contact
SSR, passive, potential free, max. 350 V
AC/DC, 150 mA, 400 mW
Weight 290 g
Dimensions (h×w×d) 91×74×60 mm (in case of the longer version, the height is 151 mm)

* for water (25°C)

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Rozměrový náčrt

Schéma zapojení

Modifikace

Soubory ke stažení

218.01en .pdf 218.01en .pdf

CONTACT

SENSIT s.r.o.

Školní 2610, 756 61 Rožnov pod Radhoštěm


+420 571 625 571

186045cc-16f8-413f-8234-88594b3001ca

NEWSLETTER

Receive news and product information in your email.

© Copyright 2022 SENSIT s.r.o. | Školní 2610, 756 61 Rožnov pod Radhoštěm, Czech Republic | +420 571 625 571 | f9f481eb-b8b4-441d-a8a2-7bc7195b762d
All Rights Reserved. Webdesign: FlexiSystems s.r.o.: e-learning, webdesign, CMS.
...