extend your senses
KOS
TR 141A - stainless steel,
-50 °C to 200 °C

TR 141A - stainless steel,
-50 °C to 200 °C

TR 141A - stainless steel,
-50 °C to 200 °C

CONFIGURATOR

CONFIGURE AND REQUEST

21452
__KOUPIT__
__NABIDKA__
__JINY DOTAZ__

BBB

--%>

These resistance temperature sensors with a cable and thermocouple temperature sensors with a cable TR 141A, are designed for measuring the surface temperature of solid substances with a flat and smooth surface. The maximum temperature range of use is -50 to 200 °C, when mounting with an M4 screw, it is recommended to apply silicone grease or thermally conductive to the measured surface, which ensures quicker response and minimizes error in the method of measurement.

The sensors are designed for use in a chemically non-aggressive environment. The method of use must be chosen with regard to the temperature and chemical resistance of the case and lead-in cable.

Temperature sensors TR 141A can be also supplied in special design for an explosive environment.

ACCESSORIES

DECLARATION, CERTIFICATION, CALIBRATION

  • Manufacturer provides EU Declaration of Conformity.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 

Technické parametry

Sensor typeTR 141A
Measuring range -50 to 200 °C (can be limited by the sensing element, determine in documentation) 
Type of sensing element*Pt, Ni, NTC, TCK, TCJ, TCT
Ingress protection IP 67 in accordance with EN 60 529, as amended 
Case material stainless steel DIN 1.4301 
Length of case L 40 mm
Lead-in cable shielded silicone 2 x 0,22 mm2
shielded silicone 4 x 0,15 mm2 
Wire resistance 0,16 Ω for 1 m of cable for 2-wire connection 
Time response τ0,5< 10 s (on flat surface of Al prism without paste) 
Recommendation use thermal conductive paste for installation
Maximum allowable cable tension 1 kg
Weight0,05 kg pro délku kabelu 1 m

*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer. 

Rozměrový náčrt

Schéma zapojení

Modifikace

  • possibility to encase two sensing elements
  • variable design of sensor case dimensions and materials
  • accuracy class A (with the exception of sensors Ni 10000/5000, Ni 10000/6180, T1 = Ni 2226, thermistor NTC 20 kΩ)
  • possibility of three or four-wire connection
  • possibility of encasing non-standard temperature sensors (DALLAS, TSic, KTY, SMT, etc.)

Soubory ke stažení

K23.05en.pdf K23.05en.pdf

CONTACT

SENSIT s.r.o.

Školní 2610, 756 61 Rožnov pod Radhoštěm


+420 571 625 571

63d68eae-4783-4536-893a-b04b34024106

NEWSLETTER

Receive news and product information in your email.

© Copyright 2022 SENSIT s.r.o. | Školní 2610, 756 61 Rožnov pod Radhoštěm, Czech Republic | +420 571 625 571 | ba4b8c89-80d1-4930-a6b5-5cb19c548296
All Rights Reserved. Webdesign: FlexiSystems s.r.o.: e-learning, webdesign, CMS.
...