These resistance-type sensors are intended for contact measurements of temperatures of liquid and gaseous substances. These sensors are produced in two versions: the small connection head with the resistance-type output and the big connection head with the output 4 to 20 mA. The sensors are designed to be used in the food-processing industry mainly. The sensor - central holder combination is suitable for temperature measurement in air condition ducts. The sensor - thermowell combination is suitable for temperature measurement in tubing. The sensor variant with welded thread is ideal for direct measuring of mediums in ducts. The standard temperature range in which the active sensors are allowed to be utilised is -50 to 150 °C, for the passive sensors the range is -50 to 200 °C. The sensors can be utilised for any control systems that are compatible with sensing element output signals or output signals quoted in the table of sensing element types.
The sensors are designed to be operated in a chemically non-aggressive environment.
ACCESSORIES
DECLARATION, CERTIFICATES, CALIBRATION
- Manufacturer provides EU Declaration of Conformity.
- Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.