diameter 5.8 mm, -40 °C to 105 °C

Description and application

TGL AND TGLJ
diameter 5.8 mm, -40 °C to 105 °C

These resistance sensors are designed to measure the temperature of gaseous and liquid substances. The maximum temperature range of use of the sensors is -40 to 105 °C. Used type of lead-in cable is a PVC type with insulation up to 80 °C with shielding up to 105 °C without shielding. The diameter of the case also enables the encasement of special temperature sensors – KTY, SMT 160, DS 18B20, TSic etc. In combination with the stainless steel thermowell JTG8, the sensor can be used for measuring the temperature in pipelines, as well as a pressure device as defined in Government Regulation no. 26/2003 coll., as amended. the sensors are designed for universal use, the method of use must be chosen with regard to the temperature and chemical resistance of the case and supply cable.

ACCESSORIES

DECLARATION, CERTIFICATION, CALIBRATION

  • Manufacturer provides EU Declaration of Conformity.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 


  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Přiložené soubory

Sensor type TGL TGLJ
Use general for JTG 8 thermowell
Measuring range
-40 to 105 °C (can be limited by the type of cable)
Type of sensing element all types
(Pt 100, Pt 1000, Ni 1000, Ni 10000,Ni 2226=T1, NTC, PTC, KTY,
TSiC, DALLAS, thermocouple K, thermocouple J, thermocouple T and so on)
Ingress protection IP 67 in accordance with EN 60529
Case material stainless steel DIN 1.4571; 1.4301
Diameter of the case
5.8 mm
Length of case L
40 and 60 mm
Lead-in cable PVC shielded 2 x 0.34 mm2 or 4 x 0.25 mm2 (-40 to 80 °C)
PVC unshielded 2 x 0.35 mm2 or 4 x 0.35 mm2 (-40 to 105 °C)
Wire resistance 0.11 Ω for 1 m of cable for 2-wire connection
Time response
τ0.5< 7 s (in flowing water 0.4 m.s-1) τ0.9< 45 s (in flowing water 0.4 m.s-1)

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.