extend Your senses
sitemap
cz en Lithuania
A selected group of goods  Products »

TG 1 and TG 2
diameter 6 mm, -50 °C to 200 °C

Description and application

TG 1 and TG 2
diameter 6 mm, -50 °C to 200 °C

These resistance sensors are designed to measure the temperature of gaseous and liquid substances. The maximum temperature range of use of the sensors is -50 to 200 °C. Used type of lead-in cable has silicone insulation and shielding. The sensors are primarily designed for measuring the temperature in pipelines. There structure enables quicker response to changes in temperature and can be used as a pressure device as defined in Government Regulation no. 26/2003 coll., as amended. The sensors are designed for universal use. The method of use must be chosen with regard to the temperature and chemical resistance of the case and lead-in cable.

ACCESORRIES

DECLARATION, CERTIFICATION, CALIBRATION

  • Manufacturer provides EU Declaratin of Conformity.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 


  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Download

Sensor type TG 1 TG 2
Measuring range
-50 to 200 °C (can be limited the type of cable,
determine in documentation)
Type of sensing element
all types (Pt 100, Pt 1000, Ni 1000, Ni 10000,Ni 2226=T1, NTC, PTC, KTY, TSiC, DALLAS, thermocouple K, thermocouple J, thermocouple T and so on)
Ingress protection
IP 67 in accordance with EN 60529
Thread / OK
M 10 x 1.5 / OK 12
Material of the case
brass stainless steel DIN1.4301
Diameter of case
6 mm
Length of case L
10 to 60 mm (in 10 mm) 10 to 100 mm (in 10 mm)
Lenght of thread L1
8 mm 10 mm
Lead-in cable
shielded silicone 2 x 0.22 mm2
shielded silicone 4 x 0.15 mm2
Wire resistance
0.16 Ω for 1 m of cabel for 2-wire connection
Time response
τ0.5 < 7 s
(in flowing water at 0.4 m.s-1)
τ0.9 < 9 s
(in flowing water at 0.4 m.s-1)

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Datasheet - TEMPERATURE SENSOR TG 1 AND TG 2
Datasheet - TEMPERATURE SENSOR TG 1 AND TG 2Datasheet - TEMPERATURE SENSOR TG 1 AND TG 2
Schéma zapojení
Rozměrový náčrt

Back to category