extend Your senses
sitemap
cz en Lithuania
A selected group of goods  Products »

TEMPERATURE TO CURRENT CONVERTERS STI AND STID (4–20 mA)

Description and application

TEMPERATURE TO CURRENT CONVERTERS STI AND STID (4–20 mA)

STI and STID converters are intended for converting the signal of Ni 1000/6180, Pt 100/3850 or Pt 1000/3850 resistance-type temperature sensing elements to the unified signal 4 to 20 mA. These converters can be utilised in any control system compatible with 4–20 mA current output. Standard measuring ranges of the converter are listed in the specifications table. Operating temperature range is -30 °C to 70 °C. These limits must not be exceeded even for a short time.

The sensors are designed to be operated in a chemically non-aggressive environment.

Two variants exist regarding to the design of the converter case:

1. STI PT and STI NI converters: the plastic case is made of POLYAMIDE material, and is identical to, for example, the connection head of s 120 sensors. It is provided with a wall bracket or with a clip for attaching to a DIN rail. the terminal board casing meets the IP 65 ingress protection requirements according to the EN 60 529 standard.

2. STID PT and STID NI converters: the plastic box is made of material TARFLON - IRY 2200, which meets requirements of UL 90 V-O standard. Itis intended for installation directly to a switchboard on a DIN rail. 

DECLARATION, CERTIFICATION, CALIBRATION

  • EU Declaration of Conformity – in accordance with Act 22/1997 Coll. on technical requirements on products as amended.
  • Calibration – The final metrological inspection – comparison with standards or working instruments – is carried out for all the products. Continuity of the standards and working measuring instruments is ensured within the meaning of the Section 5 of Act no.505/1990 on metrology. The manufacturer offers a possibility to supply the sensors calibrated in SENSIT s.r.o.’s laboratory (according to requirements of the EN ISO/IEC 17025 standard) or in an Accredited laboratory.  

 


  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Download
Converter type STI Ni
STID Ni
STI Pt 100
STID Pt 100
STI Pt 1000
STID Pt 1000
Input signal Ni 1000/6180 Pt 100/3850 Pt 1000/3850
Output signal 4 to 20 mA
Power supply (Vcc) 11 to 30 V DC (recommended value 24 V DC)
Maximum voltage ripple Vcc 0.5 %
Standard measuring range -30 °C to 60 °C
0 °C to 35 °C
0 °C to 100 °C
0 °C to 150 °C
0 °C to 250 °C
-30 °C to 60 °C
0 °C to 35 °C
0 °C to 100 °C
0 °C to 150 °C
0 °C to 200 °C
0 °C to 400 °C
-30 °C to 60 °C
0 °C to 35 °C
0 °C to 100 °C
0 °C to 150 °C
0 °C to 200 °C
0 °C to 400 °C
STI and STID ingress protection

STI: Ip 65 in accordance with EN 60 529
STI: IP 20 (plastic case) / IP 00 (terminal board) in accordance with EN 60 529

Ambient temperature -30 °C to 70 °C
Measurement error < 0.6 % of the measuring range, minimum 0.5 °C
Load resistance 50 (U - 9)
Output current for sensing element break > 24 mA
Output current for sensing element short < 3.5 mA
Sensor connection according to the wiring diagram
Recommended wire cross section STI: 0.35 to 1.5 mm2
STID: 0.35 to 4 mm2
Material of the case STI: POLYAMIDE
STID: TARFLON- IRY 2200 - meets requirements of UL 94 V-0
Operating conditions ambient temperature: -30 °C to 70 °C
relative humidity: max. 85 % (at the ambient temperature 25 °C)
atmospheric pressure: 87 to 107 kPa
Weight 0.15 kg

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

TEMPERATURE TO CURRENT CONVERTERS STI AND STID
TEMPERATURE TO CURRENT CONVERTERS STI AND STIDTEMPERATURE TO CURRENT CONVERTERS STI AND STID
Schéma zapojení
Rozměrový náčrt

Back to category