extend Your senses
sitemap
cz en Lithuania
A selected group of goods  Products »

PAIRED TEMPERATURE SENSORS TP 15, TP 15A, TP 15B

Description and application

PAIRED TEMPERATURE SENSORS TP 15, TP 15A, TP 15B

These paired temperature sensors are used as component parts of the electrical heat-quantity meters. They are produced with the Pt 100, Pt 500 and Pt 1000 temperature sensing elements. The sensors are compatible with heat-quantity meters manufactured by SIEMENS, LANDIS+GYR, KAMSTRUP, ITRON, CODEA, COMAC CAL, SENSUS METERING and others. The sensors are intended for installation in thermowells. The standard operating temperature range is 0 °C to 180 °C or 0 °C to 150 °C.

The sensors are designed to operate in a chemically non-aggressive environment.

ACCESSORIES

DECLARATION, CERTIFICATES

  • The sensors are compliant with the requirements of the EN 60 751 and EN 1434 standards and have an EU-type examination certificate no. TCM 321/07-4530.
  • EU Declaration of Conformity – he sensors are manufactured in conformity with the Directive of the european Parliament and of the council 2014/32/EC on Measuring Instruments (so-called MID).

  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Download
BASIC DATA
Type of sensing element P1 100, Pt 500, Pt 1000
Maximum measuring DC current 3 mA (Pt 100); 1.5 mA (Pt 500); 1 mA (Pt 1000)
Recommended measuring DC current 1 mA (Pt 100); 0.5 mA (Pt 500); 0.3 mA (Pt 1000)
Measuring range 0 °C to 180 °C or 0 to 150 °C
min. 2 °C or 3 °C
max. 180 °C or 150 °C
Accuracy class of individual sensors B according to EN 60 751
Sensor connection according to the wiring diagram

OTHER PARAMETERS
TP 15: 65*, 105, 140, 230 mm
The standard length of the case TP 15A: 120/91; 175/146 mm
TP 15B: 120/91; 175/146 mm
Diameter of the case 6 mm (with tolerance d10 in the length 50 mm)
Material of the case and of the thernowell stainless steel DIN 1.4301
Lead-in cable 2-wire non-shielded silicone 2 x 0.5 mm2
4-wire non-shielded silicone 4 x 0.25 mm2
Cable lenghts according to EN 1434-2, art. 3.3.4, chart 2
Wire resistance 0.07 per 1 m of the 2-wire cable
Temperature resistance of the cable -25 °C to 180 °C
Ingress protection IP 67 in accordance with EN 60 529
Insulation resistance > 100 MΩ at 100 V DC, 15 °C to 35 °C, relative humidity < 80%
Time response t0.5 < 6 s (in flowing water at 0.4 m.s-1)
Lengths of the thermowells 65*, 105, 140, 230 mm (TP 15); 91, 146 mm (TP 15 A)
Thermowell thread G1/2", M 20 x 1.5
Maximum overpressure of the thermowell 6.3 MPa

)* Producer does not recommend to use this length due to insufficient immersion of the sensor and inaccurate measurement.

Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

PAIRED TEMPERATURE SENSORS TP 15, TP 15A, TP 15
PAIRED TEMPERATURE SENSORS TP 15, TP 15A, TP 15PAIRED TEMPERATURE SENSORS TP 15, TP 15A, TP 15
Schéma zapojení
Rozměrový náčrt

Back to category