extend Your senses
sitemap
cz en Lithuania
A selected group of goods  Products »

PAIRED TEMPERATURE SENSORS TP 13, TP 13A

Description and application

PAIRED TEMPERATURE SENSORS TP 13, TP 13A

These paired temperature sensors are used as component parts of the electrical heat-quantity meters. They are produced with the Pt 100, Pt 500 and Pt 1000 temperature sensing elements. The structure of the case allows for direct installation of sensors into pipes without the need for a thermowell, thus ensuring a quick response to changes in temperature. The sensors are compatible with heat-quantity meters manufactured by SIEMENS, LANDIS+GYR, KAMSTRUP, ITRON, CODEA, COMAC CAL, SENSUS METERING and others. The standard operating temperature range is 0 °C to 180 °C or 0 °C to 150 °C.

The sensors are designed to operate in a chemically non-aggressive environment.

ACCESSORIES

  • sealing from TEMASIL material

DECLARATION, CERTIFICATES

  • The sensors are compliant with the requirements of the EN 60 751 and EN 1434 standards and have an EU-type examination certificate no. TCM 321/07-4530.
  • EU Declaration of Conformity – the sensors are manufactured in conformity with the Directive of the European Parliament and of the council 2014/32/EC on Measuring Instruments (so-called MID).

  • Specifications
  • Wiring diagram
  • Dimensional draft
  • Přiložené soubory
BASIC DATA
Type of sensing element Pt 100, Pt 500, Pt 1000
Maximum measuring DC current 3 mA (Pt 100); 1,5 mA (Pt 500); 1 mA (Pt 100)
Recommended measuring DC current 1 mA (Pt 100); 0,5 mA (Pt 500); 0,3 mA (Pt 1000)
Measuring range 0 °C to 180 °C or 0 °C to 150 °C
min. 2 °C or 3 °C
max. 180 °C or 150 °C
Accuracy class of individual sensors B in accordance with EN 60 751
Sensor connection according to the wiring diagram

OTHER PARAMETERS
Length of case 27.5 mm
Diameter of case 3.6 mm (TP 13); 5 mm (TP 13A)
Material of case stainless steel DIN 1.4301
Material of the fastening nut brass
Lead-in cable 2-wire shielded silicone 2 x 0.22 mm2
4-wire shielded silicone 4 x 0.12 mm2
Lengths of the cable according to EN 1434-2, art. 3.3.4, chart 2
Wire resistance 0.16 per 1 m of the 2-wire cable
Temperature resistance of the cable -25 °C to 180 °C
Ingress protection IP 67 in accordance with EN 60 529
Insulation resistance > 100 MΩ at 100 V DC, 15 °C to 35 °C, relaitive humidity < 80 %
Time response TP 13: t0.5 < 3 s (in flowing water at 0.4 m.s-1)
TP 13A: t0.5 < 8 s (in flowing water at 0.4 m.s-1)