The temperature sensors are designed to meet the requirements of EN 60 079-
15:2006 standard. They operate on the base of defined relationship between change
of sensing element resistance and change of temperature. They are not able to form
sparkles, electric arcs or high surface temperatures. The sensors that are identified
on the type label by II 3G Ex nA II T6 code can be utilised in explosion endangered
rooms, device group II, zone 2. The operating temperature range for using them in
zone 2 is -20 °C to 80 °C. These limits must not be exceeded even for a short time.
According to the location of the sensing element and utilization of the sensors there
are following versions:
Serie S 110 - temperature sensors for outdoor usage. Temperature sensing element
is located in a metal stem of the 25 mm length, delivering with
a plastic side holder.
Certificate FTZÚ 07 ATEX 0246X
Serie S 120 - temperature sensors for using in air condition ducts or tubing.
the sensing element is located in a metal stem of the standard length
of 70, 120, 180 a 240 mm; it is delivered with a plastic holder, optionally
the stainless steel thermowell JS 130 can be delivered.
Certificate FTZÚ 07 ATEX 0247X
Serie S 140 - contact version for measurement on piping. Sensing element is located
in the metal measure case protecting by protect case made of
SILIKON and SILAMID. Delivering with fastening strap (length 40 cm)
and closing device.
Certificate FTZÚ 07 ATEX 0249X
Serie S 160 - Fast response temperature sensors used in piping. Sensing element is located in a case the part of which is also screwing (thread G ½“, M 20x1,5) which makes possible to assembly directly in piping.
Certificate FTZÚ 07 ATEX 0251X
Fast response temperature sensors used in piping. Sensing element is located in a case the part of which is also screwing (thread G ½“, M 20 x 1,5) which makes possible to assembly directly in piping.
The plastic head is made of LEXAN 500R. The sensors meet the ingress protection requirements IP 65 according to en 60529. The head is provided by a cable ending or a connector. The sensors are designed to be operated in a chemically non-aggressive environment and they can be installed in places with low risk of mechanical stress.
Used sensing elements: Ni 1000/5000, Ni 1000/6180, Ni 891, Pt 100/3850, Pt 500/3850, Pt 1000/3850, thermistor NTC 20kΩ.
| © 2010 SENSIT s.r.o. |
Školní 2610, 756 61 Rožnov pod Radhoštěm Tel.: +420 571 625 571 E-mail: obchod@sensit.cz |
![]() |