These paired temperature sensors are used as component parts of the electrical heat quantity meters. They meet the requirements of the IEC 751 and EN 1434 standards and they carry the certificate EU of te type approval identification TCM 321/07-4530. The sensors are produced in accordance with the council Directive 2004/22/EEC relating to measure devices that was implemented to the legal system of the Czech Republic by the government regulation no. 464/2005 col.
The sensors are produced with the temperature sensing elements Pt 100, Pt 500 and Pt 1000 and they consist of a case in which the resistant-type sensing element and the metal connection head with the terminal board are fixed. The sensor cases are made of the stainless steel EN X5CrNi18-10 (DIN 1.4301) and have the diameter 6 mm (TP 16) or 3,6 mm (TP 16A). The two-wire or the four-wire connection may be connected to the sensor (the internal sensor connection uses two wires). The metal connection head is made of a alluminium alloy. Optionally, thermowells JTP 16 or JTP 16A made of the stainless steel EN X5CrNi18-10 (DIN 1.4301) can be delivered.
The sensors are designed to be operated in a chemically non-aggressive environment. The standard operating temperature range 0 to 180 °C and 0 to 150 °C.
Used sensing elements: Pt 100, Pt 500, Pt 1000.
![]() ![]() |